Free flow side to nose check valve with bypass orifice and port 3 blocked
Cavity: T-19A | Capacity:
Technical specifications
Free-flow, side-to-nose cheater check valves with a bypass orifice function as a 2-port check valve in a 3-port cavity. They allow free flow from port 2 to port 1 with a customer specified orifice that controls flow from port 1 to port 2. Port 3 of the cartridge is blocked off.
- When used in a full time regeneration circuit these valves allow full force to be developed by the cylinder when it comes to a stop. The bypass orifice drops the rod end pressure to zero when flow out of the rod stops.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity120 gpm
- Maximum Operating Pressure5000 psi
- Orifice Range.016 - .218 in.
- Valve Hex Size1 5/8 in.
- Valve Installation Torque350 - 375 lbf ft
- Model Weight1.90 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge