Loading...
Loading...

Model

DPCDLAN

Control
Adjustment Range
Seal Material
Material/Coating

3-way, pilot-operated, directional valve with internal drain to port 3 (1 to 2 open, 3 blocked)

Cavity: T-2A | Capacity:

Loading...

Model

DPCDLAN

Control
Adjustment Range
Seal Material
Material/Coating

Technical specifications

Pilot-operated, 3-way directional cartridges (1 to 2 open, 3 blocked) are switching devices typically used in moderate flow circuits. They can be used by themselves or to actuate larger pilot-operated directional cartridges or logic cartridges. The valve shifts when the pressure differential between port 1 and port 3 exceeds the setting.

  • Pressure at port 3 is directly additive to the setting of the valve. Because of this, port 3 may not be useable as a work port in your circuit. If this is a consideration, the 4 port version of this valve may be a solution.
  • Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
  • Port 3 can be blocked to prevent the valve from shifting.
  • This valve is not bistable; it is capable of modulating between the two positions shown.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar). This is due to fatigue strength limits not hydraulic operating limits.
  • When pilot pressure exceeds the valve setting, pilot flow may be a consideration. See performance curves for pilot consumption vs. load pressure above the valve setting. If this is a problem, the direct acting version of this valve would be a solution.
  • Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    15 gpm
  • Maximum Operating Pressure
    5000 psi
  • Control Pilot Flow
    10 - 15 in³/min.
  • Factory Pressure Settings Established at
    4 gpm
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    1 in³/min.@1000 psi
  • Adjustment - No. of CW Turns from Min. to Max. setting
    5
  • Valve Hex Size
    1 1/8 in.
  • Valve Installation Torque
    45 - 50 lbf ft
  • Adjustment Screw Internal Hex Size
    5/32 in.
  • Locknut Hex Size
    9/16 in.
  • Locknut Torque
    80 - 90 lbf in.
  • Model Weight
    .60 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • How big is a drop of hydraulic oil?  
  • Where would I use a DR__ instead of a DP__?
  • I used a DP** in a circuit but it hangs. What happened?
  • Direct acting or pilot operated - what do I use?

Keep up with Sun