High side, 3-position, shuttle valve
Cavity: T-34A | Capacity:
Technical specifications
High-side shuttle cartridges are most often used in full-time regeneration circuits. When both work ports (ports 2 and 4) are at equal pressures the valve is spring-centered to an all-ports-blocked position. When one of the work ports (port 2 or 4) sees a higher pressure it is connected to the common port (port 3).
- This valve provides overrunning load control in regeneration applications where the load tends to extend the cylinder. Because there is spool leakage, it does not prevent drift.
- Hardened spool/sleeve construction provides excellent wear characteristics and minimizes cross leakage.
- Although this valve goes into a 4-port cavity, the nose (port 1) is not used.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity120 gpm
- Maximum Operating Pressure5000 psi
- Maximum Valve Leakage at 110 SUS (24 cSt)5 in³/min.@1000 psi
- Valve Hex Size1 5/8 in.
- Valve Installation Torque350 - 375 lbf ft
- Model Weight2.90 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge