Loading...
Loading...

Model

X2CNLCNFA224

   
   
Control
Maximum Orifice Diameter
Seal Material
Solenoid Designation
Port and Material Designation
Coil
Model: X2CN

Solenoid-operated, rapid advance and feed flow control assembly

Capacity:

Loading...

Model

X2CNLCNFA224

   
   
Control
Maximum Orifice Diameter
Seal Material
Solenoid Designation
Port and Material Designation
Coil
Function
Meter in P
Function image
Meter out T
Function image

Technical specifications

This assembly consists of a needle valve which is a fully-adjustable orifice used to regulate flow. It is infinitely adjustable from fully closed up to the maximum orifice diameter. It is not pressure-compensated. It may be used as flow controls or as shutoff valves. The rapid or feed rate is selected by a solenoid operated (normally open or closed) 2-way, 2-position valve.

  • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • A balanced adjustment mechanism allows for easy adjustment even at high pressures.
  • Because needle valves are non-compensating devices, the fixed orifice size will regulate flow through the valve in proportion to the square root of the pressure differential across ports 1 and 2.
  • Now available with FLeX Series solenoid valves. See CONFIGURATION section, SOLENOID DESIGNATION to specify.
  • Body Type
    Sandwich
  • Interface
    ISO 03
  • Capacity
    15 gpm
  • Body Features
    Meter in P or Meter out T
  • Control Flow Range
    0 - 7 gpm
  • Seal Plate Included (see notes)
    Yes
  • Stack Height
    1.75 in.
  • Why doesn't Sun anodize their aluminum bodies?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?
  • Customer to install locating pin (included) for functional orientation desired.
  • Stack height value in technical data table includes seal retainer plate.
  • For detailed information regarding the cartridges contained in this assembly, click on the models codes shown in the Included Components tab.
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.

Keep up with Sun