Back-to-back check/shuttle valve with signal at port 3
Cavity: T-11A | Capacity:
Technical specifications
The back-to-back check valve combines two simple check valves into a single cartridge. It connects the work port with the higher pressure to the signal or common port. The signal is sensed at port 3.
- Back-to-back check cartridges feature hardened, spherically lapped, guided poppets and a lightly stressed helical spring that result in excellent wear characteristics and extremely low leakage rates.
- The back-to-back checks do not provide a means of lowering a signal. They will trap a high signal if the load pressures drop to a lower pressure. Some means of bleeding off the signal should be provided.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity2.5 gpm
- Maximum Operating Pressure5000 psi
- Maximum Valve Leakage at 110 SUS (24 cSt)5 drops/min.
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Model Weight.30 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge