Model

CDAPMCN

Control
Cracking Pressure
Seal Material

Model: CDAP

Mechanically operated, back-to-back check valve

Cavity: T-162DP | Capacity:

Model

CDAPMCN

Control
Cracking Pressure
Seal Material

Technical specifications

The phaser check is a pair of checks, back-to-back, with the poppet at port 1 mechanically actuated. The valve is meant to be installed into the piston of a cylinder. When the cylinder reaches the end of its stroke the poppet in the phaser check is shoved off its seat allowing flow through the piston. This allows two cylinders to get back into phase.

  • This valve is not designed to handle side forces. Actuating direction must be axial, and contact surface must be perpendicular to valve axis to within 5°.
  • This valve is NOT meant to be cam operated.
  • This valve is NOT to be used in place of a mechanical stop.
  • Maximum stroke of the poppet must be limited to .047 in. (1,2 mm) by a mechanical stop other than the valve itself.
  • Note: Port 2 of the T-162A cavity is not used with this valve.
  • A cylinder that does its work while extending can put a large load on the rod gland at the end of its stroke. A phaser check in the piston can limit the unnecessary force on the gland.
  • If you need to monitor the pressure in a cylinder, a phaser check can prevent the trapping of a false pressure value by a load holding valve.
  • A phaser check in the piston of a vertically mounted cylinder will bleed air at the end of the stroke.
  • Phaser checks in the pistons of master/slave cylinders will synchronize the cylinders simply by taking the mechanism to the end of its travel in both directions. This lends itself to dual cylinder steering applications.
  • Check valves offer extremely low leakage rates with a maximum leakage of less than 1 drop per minute (0,07 cc/min).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    1.25 gpm
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    1 drops/min.
  • Valve Internal Hex Size
    5/16 in.
  • Valve Hex Size
    3/4 in.
  • Valve Installation Torque
    20 - 25 lbf ft
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?