Model: CKEV

Vented pilot-to-open check valve - atmospherically referenced

Cavity: T-2A | Capacity:

Model

CKEVXCN

Control
Cracking Pressure
Seal Material

Technical specifications

This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) pilot port will open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced out the back of the hex body.

  • There is a positve seal between ports 2 and 3.
  • Pilot pressure as low as 75 psi (5 bar) higher than the pressure at the vent can prevent the valve from closing.
  • Atmospherically referenced pilot-to-open check valves are considered problem solvers for existing circuits using non-vented valves. However, the atmospherically referenced valve will eventually leak externally or allow moisture into the spring chamber. Four-port vented pilot-to-open check cartridges are recommended for new applications.
  • Pilot-to-open check cartridges are locking valves, not motion control valves. For motion control applications, use counterbalance valves.
  • Approximately 1 drop (0,07 cc) of fluid will pass from the pilot area to the vented spring chamber every 4000 cycles.
  • For models with manual load release control option, turn load release clockwise to release load.
  • Provides hose break protection, prevents loads from drifting and positively locks pressurized loads.
  • Extremely low leakage. The seat and poppet are heat treated for long life. If the load drifts due to the valve, the seat has probably been damaged by contamination and the valve should be replaced.
  • Sealed pilot for use in circuits where cross port leakage is undesirable.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    30 gpm
  • Maximum Operating Pressure
    5000 psi
  • Pilot Ratio
    3:1
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    1 drops/min.
  • Valve Hex Size
    1 1/8 in.
  • Valve Installation Torque
    45 - 50 lbf ft
  • Adjustment Screw Internal Hex Size
    1/8 in.
  • Locknut Hex Size
    7/16 in.
  • Model Weight
    .50 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?
  • What should I do if I need load holding on the rod of a high ratio cylinder?
  • What happens to the pilot-to-open check valve if I have back pressure in my system?
  • Other companies make high ratio PO checks. Why doesn't Sun?
  • Can I control the motion of a load with a pilot-to-open check valve?
  • How do I know how much pilot pressure is required to open a pilot-to-open check valve?
  • Where should I mount pilot-to-open check valves in my system?
  • Can I use pilot-to-open check valves with paired cylinders?
  • What about intensification?
  • How big is a drop of hydraulic oil?  
  • Vented pilot-to-open check valves are insensitive to pressure on the valve port (port 2), aren't they?
  • Should I replace the pilot-to-open check valve if my cylinder is drifting or moving?
  • Where should a vented valve be vented?
  • What is the actual pilot ratio of Sun's pilot to open check valves?
  • What ever happened to the Delrin seated valves?
  • What does pilot ratio refer to in a pilot-to-open check valve?
  • Direct acting or pilot operated - what do I use?
  • What is the difference between pilot-to-open check valves with sealed pilots compared to standard bleed through versions?
  • My load keeps drifting, and every time I take your valves out, the nose seals have been blown out of their grooves.
  • I want to use your pilot-to-open checks on air. Will they work?
  • Can I use a three-port vented pilot-to-open check valve instead of the four-port version to save on plumbing?