Free flow nose to side check valve with bypass orifice
Cavity: T-13A | Capacity:
Technical specifications
Free-flow, nose-to-side check valves with a bypass orifice allow free flow from port 1 to port 2. A customer specified orifice is included to restrict flow from port 2 to port 1. See technical data below for orifice range.
- Two-port check valves share the same cavity for a given frame size, however, pay close attention as flow paths may be in opposite directions.
- Will accept 5000 psi (350 bar) at ports 1 and 2.
- Valves with the opposite flow path (free flow from 2 to 1) are considered flow controls and may be found listed as fixed orifice, non-pressure compensated flow control valve with reverse flow check.
- The customer specified orifice diameter is stamped on one of the cartridge's hex faces.
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP or /LH (see CONFIGURATION section). For further details, please see the Materials of Construction page.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity15 gpm
- Maximum Operating Pressure5000 psi
- Orifice Range.016 - .107 in.
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
Highlights
Technical Tips
Technical Information