Loading...
Pilot-to-close check valve with bypass orifice
Cavity: T-19A | Capacity:
Technical specifications
This valve is a spring biased closed, pilot-to-close check cartridge with a bypass orifice. It incorporates a steel seat and is non-vented. The valve allows flow from port 1 to port 2 and restricts flow from port 2 to port 1. Pressure at the pilot (port 3) opposes pressure at port 1 at a ratio of 1.8:1. Pressure at port 2 directly opposes the pilot pressure. Note: The bypass orifice diameter is specified by the customer. See Technical Data below for the allowable orifice range.
- Features hardened steel seats for excellent wear characteristics and contamination tolerance.
- Nominal pilot ratio is 1.8:1. This means that a pressure of 1000 psi (70 bar) at the pilot port will close a valve against a pressure of 1800 psi (125 bar) at port 1. Any decay or loss of pilot pressure could allow the valve to open, even if it is a momentary decay or loss.
- Pressure at the port 2 area directly opposes pilot pressure.
- With equal pressures at all ports the valve is closed.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity160 gpm
- Orifice Range.016 - .354 in.
- Valve Hex Size1 5/8 in.
- Valve Installation Torque350 - 375 lbf ft
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
Highlights
Technical Tips
Technical Information