Loading...
Free flow nose to side check valve
Cavity: T-18A | Capacity:
Technical specifications
Free-flow, nose-to-side check valves are on/off circuit components that allow free flow from the inlet (port 1) to the outlet (port 2) and block flow in the opposite direction.
- Two-port check valves share the same cavity for a given frame size, however, pay close attention as flow paths may be in opposite directions.
- Check valves offer extremely low leakage rates with a maximum leakage of less than 1 drop per minute (0,07 cc/min).
- Will accept 5000 psi (350 bar) at ports 1 and 2.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP or /LH (see CONFIGURATION section). For further details, please see the Materials of Construction page.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity160 gpm
- Maximum Operating Pressure5000 psi
- Maximum Valve Leakage at 110 SUS (24 cSt)1 drops/min.
- Valve Hex Size1 5/8 in.
- Valve Installation Torque350 - 375 lbf ft
- Model Weight2.10 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- K65 Ninety degree with reverse flow check
- K66 Ninety degree with reverse flow check - sequence
- K68 Ninety degree with reverse flow check - sequence
- K6D Ninety degree with reverse flow check - sequence
- K6E Ninety degree with reverse flow check - sequence
- K6F Ninety degree with reverse flow check - sequence
- K6L Ninety degree with reverse flow check - sequence
- K6M Ninety degree with reverse flow check - sequence
- K6N Ninety degree with reverse flow check - sequence
- K6Q Ninety degree with reverse flow check - sequence
- K6R Ninety degree with reverse flow check - sequence
- K6S Ninety degree with reverse flow check - sequence
- K6W Ninety degree with reverse flow check - sequence
- K6X Ninety degree with reverse flow check - sequence
- K6Y Ninety degree with reverse flow check - sequence
- KB2 ISO 08: Reducer on A with reverse flow check
- KB3 ISO 08: Reducer on B with reverse flow check
- LN5 Ninety degree with reverse flow check
- LN6 Ninety degree with reverse flow check
- LN8 Ninety degree with reverse flow check
- LND Ninety degree with reverse flow check
- LNE Ninety degree with reverse flow check
- LNF Ninety degree with reverse flow check
- LNL Ninety degree with reverse flow check
- LNM Ninety degree with reverse flow check
- LNN Ninety degree with reverse flow check
- LNQ Ninety degree with reverse flow check
- LNR Ninety degree with reverse flow check
- LNS Ninety degree with reverse flow check
- LNW Ninety degree with reverse flow check
- LNX Ninety degree with reverse flow check
- LNY Ninety degree with reverse flow check
- QB3 ISO 08: Reducer/reliever on B with reverse flow check and port 4 external
- Z3L ISO 08: Priority flow control on A with reverse flow check
- Z3M ISO 08: Priority flow control on B with reverse flow check
Highlights
Technical Tips
Technical Information