3-way solenoid-operated directional spool valve - pilot capacity (740 Series)

Cavity: T-9A | Capacity:

Loading...

Model

DBAFMXCN

Control
Spool Configuration
Seal Material
Coil
See CAD Files tab below to request images.

Technical specifications

This solenoid-operated 3-way, 2-position cartridge is a direct-acting, balanced spool pilot valve used to pilot other full-flow valves. The valve is normally open between port 1 and port 2 or port 1 and port 3 and all flow paths are bidirectional. This valve is designed to be used with 740 and 747 Series coils.

  • The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
  • This valve is direct actuated and requires no minimum hydraulic pressure for operation.
  • Valves exhibit extremely low leakage rates; less than 10 drops/min. @ 5000 psi (0,7 cc/min @ 350 bar).
  • This cartridge utilizes 740 Series low-power and high-power coils, and 747 Series hazardous location coils for both Normally Open and Normally Closed configurations.
  • This cartridge has an option for manual override. See the CONFIGURATION section.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
  • Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • A FULL DATA SHEET is available for this model using the link at the top of the page.
  • This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
  • A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
  • Coils can be mounted on the tube in either direction.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    .25 gpm
  • Maximum Operating Pressure
    5000 psi
  • Manual Override Force Requirement
    10 lbs/1000 psi @ Port 1
  • Manual Override Stroke
    .10 in.
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    10 drops/min.@5000 psi
  • Response Time - Typical
    50 ms
  • Switching Frequency
    15,000 max. cycles/hr
  • Solenoid Tube Diameter
    .63 in.
  • Valve Hex Size
    7/8 in.
  • Valve Installation Torque
    20 - 25 lbf ft
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?
  • DBAFS 3-way, soft shift, solenoid-operated directional spool valve - pilot capacity (740 Series)
  • 991283 740 Series momentary/twist operation, manual override control kit, T control
  • 991284 740 Series detent/lock operation, manual override control kit, L control
  • 991285 740 Series dual twist/lock operation, manual override control kit, D control
  • 991301 740 Series, red momentary/twist operation, manual override control kit, T control
  • 991302 740 Series, red detent/lock operation, manual override control kit, L control
  • 991303 740 Series, red dual twist/lock operation, manual override control kit, D control
  • Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
  • An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.