FLeX Series 2-way, 2-stage, solenoid-operated directional poppet valve with reverse flow check - flow 2-1, 3000 psi (210 bar)
Cavity: T-162A | Capacity:
Technical specifications
This FLeX Series solenoid-operated 2-way, 2-stage cartridge is a pilot-operated directional poppet valve. The valve is low leakage and available in either a normally open or normally closed configuration to control flow from port 2 to port 1. A reverse flow check will allow flow from 1 to 2 in the closed condition. In the open condition, flow from 1 to 2 will cause the valve to auto-close and pilot flow will pass from 1 to 2.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- Designed and tested to 10-million operational cycles at full-rated pressure.
- Exceeds new NFPA test standard T2.6.1 R2014 for fatigue and burst pressure ratings.
- Higher flow rates than competing valves of similar size.
- Designed using CFD simulation for optimized geometries.
- All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
- Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
- This valve exhibits extremely low leakage - 0.004 in3 (0,07 cc)/min (1 drop/min).
- This cartridge utilizes both 740 Series low-power and 747 Series hazardous location coils.
- This valve is available with a manual push-type override option for normally open versions only.
- Models equipped with the P control pull-type manual override allow the operator to shift the valve into a mechanically detented position by fully pulling then twisting the override counter-clockwise. This detented position will be maintained until the operator pulls and twists the manual override clockwise and allows the valve to return to its de-energized position. This pull-type manual override assembly requires a pull force of approximately 15 lbf in. (1,7 Nm) and has a mechanical life expectancy of approximately 2,000 cycles.
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- A FULL DATA SHEET is available for this model using the link at the top of the page.
- A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity10 gpm
- Maximum Operating Pressure3000 psi
- Check Cracking Pressure50 psi
- Maximum Valve Leakage at 110 SUS (24 cSt)0.004 in³/min.@3000 psi
- Viscosity Range35 - 2000 SUS
- Response Time - Typical50 ms
- Switching Frequency15,000 max. cycles/hr
- Valve Hex Size3/4 in.
- Valve Installation Torque20 - 25 lbf ft
- Model Weight5.6 oz.
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
What is the difference between nominal and maximum flow capacity?
What is the flow performance limit of DF** FLeX cartridges?
Do FLeX valves utilize a floating nose design?
Is the FLeX program available in QuickDesign SmartConnect?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- 991283 740 Series momentary/twist operation, manual override control kit, T control
- 991284 740 Series detent/lock operation, manual override control kit, L control
- 991285 740 Series dual twist/lock operation, manual override control kit, D control
- 991301 740 Series, red momentary/twist operation, manual override control kit, T control
- 991302 740 Series, red detent/lock operation, manual override control kit, L control
- 991303 740 Series, red dual twist/lock operation, manual override control kit, D control
- Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
- An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
Highlights
Technical Tips
Technical Information