Model: DKDR

Normally closed, balanced poppet, logic element - vent-to-open

Cavity: T-21A | Capacity:

Model

DKDRXHN

Control
Minimum Pilot Pressure
Seal Material
Material/Coating

Technical specifications

This is a normally closed, balanced poppet, switching element. When the vent port (port 4) is blocked, the poppet remains in the closed position. Venting port 4 shifts it to the open position, provided there is sufficient pressure at port 3.

  • Unique balanced construction provides predictable switching with 5000 psi (350 bar) at both ports 1 and 2, with the vent (port 4) open and a minimum pilot pressure of 400 psi (30 bar) at port 3.
  • Port 1 and port 2 are fully sealed from port 3 and port 4. Ports 3 and 4 are positively sealed.
  • Leakage rate between port 1 and port 2 is very low, typically less than 10 drops/min. at 5000 psi (0,7 cc/min at 350 bar).
  • Valve will reseat when the pilot pressure falls below 145 psi (10 bar).
  • Port 4 may be externally connected to a pilot switching valve. The pilot valve should have a leakage rate of less than 10 drops/min. and be able to satisfy the pilot flow requirements. Sun model DAA*-*** solenoid pilot valve is ideal for this application.
  • All ports will accept 5000 psi (350 bar).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    15 gpm
  • Maximum Operating Pressure
    5000 psi
  • Minimum Pilot Pressure Required to Shift Valve
    400 psi
  • Control Pilot Flow
    See Performance Data
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    10 drops/min.@5000 psi
  • Valve Hex Size
    7/8 in.
  • Valve Installation Torque
    30 - 35 lbf ft
  • Model Weight
    .35 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?
  • DKDR8 Normally closed, balanced poppet, logic element with integral T-8A control cavity - vent-to-open