Loading...
Loading...

Model

DKJR8HN

Minimum Control Pressure
Seal Material

Normally closed, balanced poppet, logic element with integral T-8A control cavity - vent-to-open

Cavity: T-24A | Capacity:

Loading...

Model

DKJR8HN

Minimum Control Pressure
Seal Material

Technical specifications

This is a normally closed, balanced poppet, switching element with an integral T-8A control cavity. With a 2-way valve in the closed position installed in the T-8A control cavity, the poppet remains closed. Opening the 2-way valve shifts the poppet to the open position, provided there is sufficient pressure at port 3.

  • Unique balanced construction provides predictable switching with 5000 psi (350 bar) at port 1 and port 2. Switching will only occur when both a minimum pilot pressure of 400 psi (30 bar) is present and pilot control valve is open.
  • These valves are hydraulically balanced between port 1 and port 2.
  • Port 1 and port 2 are fully sealed from port 3 and port 4. Ports 3 and 4 are positively sealed.
  • Any backpressure at the drain port is directly additive to the required pilot pressure for reliable operation.
  • Leakage rate between port 1 and port 2 is very low, typically less than 10 drops/min. at 5000 psi (0,7 cc/min at 350 bar).
  • Valve will reseat when the pilot pressure falls below 145 psi (10 bar).
  • NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve should then be installed into the main stage valve to its required torque value.
  • The -8 control option allows the pilot control valve to be incorporated directly into the end of the logic cartridge via the T-8A cavity. These pilot control cartridges are sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation. See Pilot Control Cartridges.
  • All ports will accept 5000 psi (350 bar).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    120 gpm
  • Maximum Operating Pressure
    5000 psi
  • Minimum Pilot Pressure Required to Shift Valve
    300 psi
  • Control Pilot Flow
    See Performance Data
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    10 drops/min.@5000 psi
  • Pilot Control Cavity
    T-8A
  • Pilot Control Valve Hex Size
    7/8 in.
  • Pilot Control Valve Installation Torque
    20 - 25 lbf ft
  • Valve Hex Size
    1 5/8 in.
  • Valve Installation Torque
    350 - 375 lbf ft
  • Model Weight
    2.50 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?
  • DKJR Normally closed, balanced poppet, logic element - vent-to-open
  • Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at point of use.

Keep up with Sun