Model: DMDA
3-way, solenoid-operated directional spool valve
Cavity: T-11A | Capacity:
Model
DMDAXNN
X-Control, A-Spool
![](https://cmsimages.sunhydraulics.com/DMDA-XA.gif)
Technical specifications
This solenoid-operated 3-way, 2-position cartridge is a direct-acting, balanced spool directional valve.
- The solenoid tube assembly is fatigue rated for 5000 psi (350 bar) service.
- Spools B and R are closed in the transition between their two positions. This results in a higher performance limit at the expense of lower capacity. When used as pilot controls, where capacity is not a factor, the closed transition will provide faster and more consistent response times.
- This valve is direct actuated and requires no minimum hydraulic pressure for operation.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
- Coils are interchangeable with other Sun Series 1 solenoid products and can be mounted on the tube in either direction.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity12 gpm
- Maximum Operating Pressure5000 psi
- Manual Override Force Requirement5 lbs/1000 psi @ Port 1
- Manual Override Stroke.10 in.
- Maximum Valve Leakage at 110 SUS (24 cSt)5 in³/min.@3000 psi
- Response Time - Typical50 ms
- Switching Frequency15,000 max. cycles/hr
- Solenoid Tube Diameter.75 in.
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Model Weight.60 lb
- Seal and nut kit - Coil
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
What parts of the Sun cartridge valve are field serviceable?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
- An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.