Model

DMUQXHN

X-Control, H-Spool
Control
Spool Configuration
Seal Material
Coil

Model: DMUQ

3-way, direct-acting, balanced spool, solenoid-operated directional valve, 1600 psi (110 bar) - common cavity

Cavity: SC-10-03 | Capacity:

Model

DMUQXHN

X-Control, H-Spool
Control
Spool Configuration
Seal Material
Coil

Technical specifications

This solenoid-operated 3-way, 2-position cartridge is a direct-acting, balanced spool directional valve. This valve is designed to be used with the 780 Series coils.

  • This valve is direct actuated and requires no minimum hydraulic pressure for operation.
  • Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
  • The metal coil nut is a functional feature of the valve and should be correctly installed for proper performance of the valve.
  • All ports are rated to a maximum operating pressure of 1600 psi (110 bar).
  • The solenoid tube assembly is fatigue rated to 1600 psi (110 bar) service.
  • The cartridge installation torque of 26 lbf ft (35 Nm) should be respected for best performance.
  • This valve utilizes a wet armature design. This means that the working fluid surrounds the armature and is exposed to the heat generated by the coil. This can be a factor if the coil is energized for long periods of time. Some fluids, notably water/glycol mixtures, break down at these temperatures over time and form varnishes that will affect the function of the cartridge.
  • Coils can be mounted on the tube in either direction.
  • Cavity
  • Series
  • Capacity
    7 gpm
  • Maximum Operating Pressure
    1600 psi
  • Typical Valve Leakage at 110 SUS (24cSt)
    1.1 in³/min.@1600 psi
  • Response Time - Typical
    50 ms
  • Switching Frequency
    15,000 max. cycles/hr
  • Solenoid Tube Diameter
    .50 in.
  • Coil Nut Torque
    3.5 - 3.9 lbf ft
  • Valve Hex Size
    25 mm
  • Valve Installation Torque
    24 - 28 lbf ft
  • Model Weight
    .30 lb

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?