Model

DRBBLANV

Control
Adjustment Range
Seal Material
Material/Coating

2-way, direct-acting, directional valve with internal drain to port 3 - normally closed

Cavity: T-11A | Capacity:

Loading...

Model

DRBBLANV

Control
Adjustment Range
Seal Material
Material/Coating
See CAD Files tab below to request images.

Technical specifications

Normally closed, direct-acting, 2-way directional cartridges are switching devices typically used in moderate flow circuits. They can be used by themselves or to actuate larger pilot-operated directional cartridges or logic cartridges. The valve shifts when the pressure differential between port 1 and port 3 exceeds the setting.

  • Pressure at port 3 is directly additive to the setting of the valve. Because of this, port 3 may not be useable as a work port in your circuit. If this is a consideration, the 4 port version of this valve may be a solution.
  • Because of their direct-acting design, these cartridges feature low internal leakage and low pilot flow consumption.
  • Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
  • This valve is not bistable; it is capable of modulating between the two positions shown.
  • Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    7 gpm
  • Maximum Operating Pressure
    5000 psi
  • Factory Pressure Settings Established at
    4 gpm
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    2 in³/min.
  • Adjustment - No. of CW Turns from Min. to Max. setting
    5
  • Valve Hex Size
    7/8 in.
  • Valve Installation Torque
    30 - 35 lbf ft
  • Adjustment Screw Internal Hex Size
    5/32 in.
  • Locknut Hex Size
    9/16 in.
  • Locknut Torque
    80 - 90 lbf in.
  • Model Weight
    .60 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • How big is a drop of hydraulic oil?  
  • Where would I use a DR__ instead of a DP__?
  • I used a DP** in a circuit but it hangs. What happened?
  • Direct acting or pilot operated - what do I use?
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.

Keep up with Sun