3-way, direct-acting, fixed setting, directional valve with drain to port 4 (1 blocked, 2 to 3 open)
Cavity: T-21A | Capacity:
See CAD Files tab below to request images.
Technical specifications
Direct-acting, 3-way directional cartridges (1 blocked, 2 to 3 open) are switching devices typically used in moderate flow circuits. They can be used by themselves or to actuate larger pilot-operated directional cartridges or logic cartridges. The valve shifts when the pressure differential between port 1 and port 4 exceeds the setting.
- Port 3 can be used as a work port.
- The flow path between port 2 and port 3 is bidirectional.
- Because of their direct-acting design, these cartridges feature low internal leakage and low pilot flow consumption.
- Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
- Pressure at port 4 is directly additive to the setting of the valve.
- This valve is not bistable; it is capable of modulating between the two positions shown.
- The flow path between port 1 and port 2 is bidirectional.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar). This is due to fatigue strength limits not hydraulic operating limits.
- Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity7 gpm
- Maximum Operating Pressure5000 psi
- Factory Pressure Settings Established at4 gpm
- Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Model Weight.55 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
What parts of the Sun cartridge valve are field serviceable?
How big is a drop of hydraulic oil?
Where would I use a DR__ instead of a DP__?
I used a DP** in a circuit but it hangs. What happened?
Direct acting or pilot operated - what do I use?
- DRBO 3-way, direct-acting, directional valve with drain to port 4 (1 blocked, 2 to 3 open)
Highlights
Technical Tips
Technical Information