Model

DRBPXN

Seal Material

3-way, direct-acting, fixed setting, directional valve with drain to port 4 (1 to 2 open, 3 blocked)

Cavity: T-21A | Capacity:

Loading...

Model

DRBPXN

Seal Material
See CAD Files tab below to request images.

Technical specifications

Direct-acting, 3-way directional cartridges (1 to 2 open, 3 blocked) are switching devices typically used in moderate flow circuits. They can be used by themselves or to actuate larger pilot operated directional cartridges or logic cartridges. The valve shifts when the pressure differential between port 1 and port 4 exceeds the setting.

  • Port 3 can be used as a work port.
  • The flow path between port 2 and port 3 is bidirectional.
  • Because of their direct-acting design, these cartridges feature low internal leakage and low pilot flow consumption.
  • Direct-acting and pilot-operated versions of these valves are interchangeable. They fit the same cavities and have the same flow paths.
  • Pressure at port 4 is directly additive to the setting of the valve.
  • This valve is not bistable; it is capable of modulating between the two positions shown.
  • The flow path between port 1 and port 2 is bidirectional.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar). This is due to fatigue strength limits not hydraulic operating limits.
  • Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    7 gpm
  • Maximum Operating Pressure
    5000 psi
  • Factory Pressure Settings Established at
    4 gpm
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    2 in³/min.
  • Valve Hex Size
    7/8 in.
  • Valve Installation Torque
    30 - 35 lbf ft
  • Model Weight
    .55 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • How big is a drop of hydraulic oil?  
  • Where would I use a DR__ instead of a DP__?
  • Direct acting or pilot operated - what do I use?
  • DRBP 3-way, direct-acting, directional valve with drain to port 4 (1 to 2 open, 3 blocked)

Keep up with Sun