DSIXXCN

Control
Minimum Control Pressure
Seal Material

3-way, 2-position, vent-to-shift diverter valve, normally closed

Cavity: T-34A | Capacity:

Loading...

Model

DSIXXCN

Control
Minimum Control Pressure
Seal Material

Technical specifications

This is a vent-to-shift, 2-position, diverter valve that is normally closed. When port 1 is vented, the pressure differential between port 3 and port 1 exceeds the spring force causing the valve to shift, thereby connecting port 3 with ports 2 and 4.

  • This valve is not bistable; it is capable of modulating between the two positions shown.
  • Vent flow out of port 1 is pressure compensated and is listed in Technical Data.
  • There must be a pressure source at port 3, relative to port 1, to shift the valve.
  • One application of this valve is to bypass divider/combiner valves in a limited-slip tractive circuit. Closed, the oil must go through the divider/combiner valves. Open, there is a large path around the divider/combiner valves for efficient high speed operation.
  • One pilot valve may be used to vent multiple diverter valves if blocking checks are used at port 1 of each diverter. If blocking checks are not used there will be interaction between high and low pressure legs of the circuit.
  • The vent-to-shift function is self cleaning and therefore insensitive to contamination.
  • Hardened spool and sleeve provide consistent and low spool leakage rates and excellent wear characteristics.
  • Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

Model CAD Files