Model

DTAFXCN

M-Control, C-Poppet
Control
Poppet Configuration
Seal Material
Coil

Model: DTAF

FLeX Series 2-way, direct-acting, solenoid-operated directional blocking poppet valve

Cavity: T-8A | Capacity:

Model

DTAFXCN

M-Control, C-Poppet
Control
Poppet Configuration
Seal Material
Coil

Technical specifications

This FLeX Series solenoid-operated 2-way, 2-position cartridge is a direct-acting directional poppet valve. Available in either normally open or normally closed configurations, these valves feature a pressure-balanced design, low leakage, and allow flow or blocking in both directions. This cartridge can be installed directly into a cavity in the end of many of Sun's pilot operated and ventable valves to provide integrated pilot control.

  • Cartridge can be installed directly into a cavity in some Sun pilot operated and ventable cartridges to provide electrically operated pilot control functions. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function.
  • Suitable for load-holding applications when configured as Normally Closed. In the event of power failure, the valve will close.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Designed and tested to 10-million operational cycles at full-rated pressure.
  • Exceeds new NFPA test standard T2.6.1 R2014 for fatigue and burst pressure ratings.
  • Higher flow rates than competing valves of similar size.
  • Designed using CFD simulation for optimized geometries.
  • All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
  • Normally Closed configuration can be used with any of the 740 Series coils, which include low-power, high-power, and 747 Series explosion-proof coils. Normally Open configuration can be used with the high-power and explosion proof coils only.
  • Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
  • This valve is available with a manual push-type override option.
  • This valve exhibits extremely low leakage - 0.004 in3 (0,07 cc)/min (1 drop/min).
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • A FULL DATA SHEET is available for this model using the link at the top of the page.
  • A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    7 gpm
  • Maximum Operating Pressure
    5000 psi
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    0.004 in³/min.@5000 psi
  • Viscosity Range
    35 - 2000 SUS
  • Response Time - Typical
    50 ms
  • Switching Frequency
    15,000 max. cycles/hr
  • Valve Hex Size
    3/4 in.
  • Valve Installation Torque
    20 - 25 lbf ft
  • Model Weight
    5.6 oz.
  • Seal and nut kit - Coil
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • U.S. Patent #
    10,302,201

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • Why is the minimum opening pressure (bias spring pressure) on pilot-operated FLeX cartridges lower than competitor product?
  • What is the flow performance limit of pilot-operated FLeX cartridges?
  • What is the difference between nominal and maximum flow capacity?
  • Do FLeX valves utilize a floating nose design?
  • Is the FLeX program available in QuickDesign SmartConnect?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
  • Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
  • An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.
  • 991283 740 Series momentary/twist operation, manual override control kit, T control
  • 991284 740 Series detent/lock operation, manual override control kit, L control
  • 991285 740 Series dual twist/lock operation, manual override control kit, D control
  • 991301 740 Series, red momentary/twist operation, manual override control kit, T control
  • 991302 740 Series, red detent/lock operation, manual override control kit, L control
  • 991303 740 Series, red dual twist/lock operation, manual override control kit, D control
  • DTAFS FLeX Series 2-way, soft shift, solenoid-operated directional poppet valve - pilot capacity