Loading...
2-way, direct-acting, balanced poppet solenoid-operated directional valve - common cavity
Cavity: SC-08-02 | Capacity:
Technical specifications
This solenoid-operated, 2-way, 2-position cartridge is a direct-acting, directional balanced poppet valve.
- This valve is direct actuated and requires no minimum hydraulic pressure for operation.
- The solenoid tube assembly is fatigue rated for 3600 psi (250 bar) service.
- The cartridge installation torque of 22 lbf ft (30 Nm) should be respected for best performance.
- All ports are rated to a maximum operating pressure of 3600 psi (250 bar).
- The valve is available with a manual push-type, with detent, override option (L control). This option is also fatigue rated for 5000 psi (350 bar).
- Coil connector options offer ratings up to IP67. See individual coil product pages for details.
- The metal coil nut is a functional feature of the valve and should be correctly installed for proper performance of the valve.
- Coils can be mounted on the tube in either direction.
- Cavity
- Series
- Capacity6 gpm
- Maximum Operating Pressure3600 psi
- Maximum Valve Leakage at 110 SUS (24 cSt)15 drops/min.@3600 psi
- Response Time - Typical50 ms
- Switching Frequency15,000 max. cycles/hr
- Solenoid Tube Diameter.51 in.
- Coil Nut Torque3.5 - 3.9 lbf ft
- Valve Hex Size7/8 in.
- Valve Installation Torque21 - 23 lbf ft
- Model Weight.35 lb
- Seal kit - Cartridge