Can't find the manifold you're looking for? Try our QuickDesign tool!
Loading...
Loading...

Model

E6I

   
   
Modifier
Model: E6I

Ninety degree with reverse flow check - sequence

Cavity: T-11A

Loading...

Model

E6I

   
   
Modifier
Function
Function image

Technical specifications

  • Modifiers
    Ports
    • E6I, /10, /11, /15, /16, /S, /S3, /S4, /V, /Y, /Y3, /Y4
      Ports 1, 2, 3: SAE 6; Gage Port: 1/4" NPTF;
    • Body Type
      Line mount
    • Cavity
    • Interface
      None
    • Body Features
      Ninety degree with reverse flow check - sequence
    • Check Cracking Pressure
      30 psi
    • Open Cavities
      1
    • Port Size
      SAE 6
    • Mounting Hole Diameter
      .34 in.
    • Mounting Hole Depth
      Through
    • Mounting Hole Quantity
      2
    • Why doesn't Sun anodize their aluminum bodies?
    • How big is a drop of hydraulic oil?  
    • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.