Loading...
Fixed-orifice pressure compensated flow control valve with reverse flow check
Cavity: T-5A | Capacity:
See CAD Files tab below to request images.
Technical specifications
Fixed-orifice, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. An integral high-capacity check valve provides unrestricted flow from port 2 to port 1.
- All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Customer must select a nominal flow setting range from the available options. Factory flow settings are within +/- 10% of the nominal flow setting for the “L” and “K” controls and within +/- 15% for the “X” control.
- The tunable control options, “L” control and “K” control, provide +/- 25% variation from the nominal factory pre-set flow. Turn the adjustment clockwise to increase flow and counterclockwise to decrease it.
- Cavity
- Series
- Capacity12 gpm
- Maximum Operating Pressure5000 psi
- Valve Hex Size1 1/8 in.
- Valve Installation Torque45 - 50 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Model Weight.40 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
What parts of the Sun cartridge valve are field serviceable?
How big is a drop of hydraulic oil?
Highlights
Technical Tips
Technical Information