Model

FDCBLAN

Control
Adjustment Range
Seal Material
Material/Coating

Fully adjustable pressure compensated flow control valve with reverse flow check

Cavity: T-5A | Capacity:

Loading...

Model

FDCBLAN

Control
Adjustment Range
Seal Material
Material/Coating

Technical specifications

Fully adjustable, pressure-compensated flow controls with reverse-flow check provide precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. They are infinitely adjustable from nearly closed up to the maximum flow. An integral high-capacity check valve provides unrestricted flow from port 2 to port 1.

  • All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
  • A balanced adjustment mechanism allows for easy adjustment even at high pressures.
  • The sharp-edged orifice design minimizes flow variations due to viscosity changes.
  • Minimum leakage is .2 gpm (0,8 L/min) when the adjustment mechanism is turned to the shut-off position.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Cavity
  • Series
  • Capacity
    12 gpm
  • Maximum Operating Pressure
    5000 psi
  • Adjustment - No. of CCW Turns from Fully Closed to Fully Open
    5
  • Valve Hex Size
    1 1/8 in.
  • Valve Installation Torque
    45 - 50 lbf ft
  • Adjustment Screw Internal Hex Size
    5/32 in.
  • Locknut Hex Size
    9/16 in.
  • Locknut Torque
    80 - 90 lbf in.
  • Model Weight
    .60 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • How big is a drop of hydraulic oil?  
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.

Keep up with Sun