Loading...
Loading...

Model

FMDBXCN

Control
Flow Rate
Seal Material
Coil

Electro-proportional 3-way flow control valve, meter in

Cavity: T-11A | Capacity:

Loading...

Model

FMDBXCN

Control
Flow Rate
Seal Material
Coil

Technical specifications

This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 connected to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control. Flow in the 2 to 3 direction is not proportional.

  • The transition between positions is closed.
  • Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
  • These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
  • The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
  • All ports will accept 5000 psi (350 bar).
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
  • The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    6 gpm
  • Manual Override Force Requirement
    5 lbs/1000 psi @ Port 1
  • Manual Override Stroke
    .10 in.
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    2 in³/min.@1000 psi
  • Solenoid Tube Diameter
    .75 in.
  • Valve Hex Size
    7/8 in.
  • Valve Installation Torque
    30 - 35 lbf ft
  • Model Weight (with coil)
    1.10 lb
  • Seal and nut kit - Coil
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Hysteresis (with dither)
    <4%
  • Hysteresis with DC input
    <8%
  • Linearity (with dither)
    <2%
  • Repeatability (with dither)
    <2%
  • Recommended dither frequency
    140 Hz
  • Deadband, nominal (as a percentage of input)
    60%

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • What happens if I block the control flow (priority) port?
  • I have a heat problem, will Sun's priority flow control help?
  • How big is a drop of hydraulic oil?  
  • What is the pressure drop through a flow control?
  • What is the compensating pressure of Sun's flow controls?
  • How accurate are Sun's flow controls?
  • What happens if I block the bypass port on a priority flow control?
  • 991055 T-11A cavity, weatherized coil seal kit
  • 991225 Momentary/twist operation, manual override control kit, T control
  • 991226 Detent/lock operation, manual override control kit, L control
  • 991227 Dual twist/lock operation, manual override control kit, D control
  • 991238 Momentary/twist operation, extended resolution, manual override control kit, E control
  • 991240 Red momentary/twist operation, manual override control kit, T control
  • 991241 Red detent/lock operation, manual override control kit, L control
  • 991242 Red dual twist/lock operation, manual override control kit, D control
  • 991243 Red momentary/twist operation, extended resolution, manual override control kit, E control
  • Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.