Loading...
Electro-proportional 3-way flow control valve, meter in
Cavity: T-11A | Capacity:
Technical specifications
This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 connected to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1 to 2 direction and with the addition of an external compensator will provide pressure compensated flow control. Flow in the 2 to 3 direction is not proportional.
- The transition between positions is closed.
- Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- All ports will accept 5000 psi (350 bar).
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- On models equipped with the D or L control, the detent mechanism in the manual override is meant for temporary actuation. The D, E, L and T manual control assemblies have a mechanical life expectancy of approximately 7,000 cycles.
- The momentary/twist override option "E" allows the operator to shift the valve by twisting the manual override clockwise 90 degrees.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity6 gpm
- Manual Override Force Requirement5 lbs/1000 psi @ Port 1
- Manual Override Stroke.10 in.
- Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi
- Solenoid Tube Diameter.75 in.
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Model Weight (with coil)1.10 lb
- Seal and nut kit - Coil
- Seal kit - Cartridge
- Seal kit - Cartridge
- Hysteresis (with dither)<4%
- Hysteresis with DC input<8%
- Linearity (with dither)<2%
- Repeatability (with dither)<2%
- Recommended dither frequency140 Hz
- Deadband, nominal (as a percentage of input)60%
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
What happens if I block the control flow (priority) port?
I have a heat problem, will Sun's priority flow control help?
How big is a drop of hydraulic oil?
What is the pressure drop through a flow control?
What is the compensating pressure of Sun's flow controls?
How accurate are Sun's flow controls?
What happens if I block the bypass port on a priority flow control?
- 991055 T-11A cavity, weatherized coil seal kit
- 991225 Momentary/twist operation, manual override control kit, T control
- 991226 Detent/lock operation, manual override control kit, L control
- 991227 Dual twist/lock operation, manual override control kit, D control
- 991238 Momentary/twist operation, extended resolution, manual override control kit, E control
- 991240 Red momentary/twist operation, manual override control kit, T control
- 991241 Red detent/lock operation, manual override control kit, L control
- 991242 Red dual twist/lock operation, manual override control kit, D control
- 991243 Red momentary/twist operation, extended resolution, manual override control kit, E control
- Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
Highlights
Technical Tips
Technical Information