Technical specifications

This valve is a 3-way, meter-in, electro-proportional throttle. The flow path, unenergized, has the supply blocked at port 1 and port 2 is drained to tank at port 3. Energizing the coil generates a closing force on the spool, creating a metering orifice in the 1 to 2 direction that is proportional to the coil command current. The valve self-compensates in the 1-to-2 direction and with the addition of an external compensator will provide pressure compensated flow control. Flow in the 2-to-3 direction is not proportional and is limited in the interest of increased resolution and capacity. Flow capacity in the 2-to-3 direction is about 1.5 gpm (6 L/min). This valve is meant to be used in a circuit that has a separate passage to tank such as a cushion lock circuit. Two FMDFs in conjunction with a cushion lock circuit create a meter-in/meter-out 3-position 4-way.

  • Note: Flow in the 2 to 3 direction is limited to about 1.5 gpm (5 L/pm).
  • The transition between positions is closed.
  • Using 2 3-ways to create a 4-way allows one to choose existing flow ranges instead of cutting a special spool.
  • These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
  • The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
  • For optimum performance, an amplifier with current feedback and adjustable dither (100 - 250 Hz) should be used.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    9 gpm
  • Maximum Operating Pressure
    5000 psi
  • Manual Override Force Requirement
    5 lbs/1000 psi @ Port 1
  • Manual Override Stroke
    .10 in.
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    2 in³/min.@1000 psi
  • Solenoid Tube Diameter
    .63 in.
  • Valve Hex Size
    7/8 in.
  • Valve Installation Torque
    30 - 35 lbf ft
  • Hysteresis (with dither)
    <4%
  • Hysteresis with DC input
    <8%
  • Linearity (with dither)
    <2%
  • Repeatability (with dither)
    <2%
  • Recommended dither frequency
    140 Hz

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • What happens if I block the control flow (priority) port?
  • I have a heat problem, will Sun's priority flow control help?
  • How big is a drop of hydraulic oil?  
  • What is the pressure drop through a flow control?
  • What is the compensating pressure of Sun's flow controls?
  • How accurate are Sun's flow controls?
  • What happens if I block the bypass port on a priority flow control?
  • Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
  • An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.

Keep up with Sun