Model

FPBUXCN

Control
Flow Rate
Seal Material
Coil

FLeX Series electro-proportional, blocking poppet throttle - normally closed

Cavity: T-162A | Capacity:

Loading...

Model

FPBUXCN

Control
Flow Rate
Seal Material
Coil

Technical specifications

This valve is a normally closed, electro-proportional, blocking poppet throttle that is spring-biased closed. Energizing the coil generates an opening force on the poppet proportional to the command current, and this force is countered by the spring and flow forces. This force balance creates a metering orifice whose effective size is proportional to the current. The valve exhibits a large degree of self-compensation in the 2-to-1 direction and will provide proportional flow control in the 1-to-2 direction with the addition of an external compensator. Full reverse flow (1-to-2) with 100% command in the 1-to-2 direction is possible without a compensator under all conditions.

  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • FLeX Series proportional valves are fully compatible with the XMD Expandable Mobile Drivers from Sun.
  • Exceeds new NFPA test standard T2.6.1 R2014 for fatigue and burst pressure ratings.
  • Designed using CFD fluid simulation for optimized geometries.
  • Capacities rated at 200-psi (14-bar) differential.
  • All configurations of this valve include zinc-nickel plating as standard for 1000-hour salt fog protection.
  • This valve can be used with both the 740 Series high-power coils and 747 Series hazardous location coils.
  • A wide variety of coil termination and voltage options are available, with and without surge protection. See the CONFIGURATION section.
  • Coil connector options offer ratings up to IP69K. See individual coil product pages for details.
  • Designed and tested to 1 million on-off operational cycles.
  • Direct actuated and requires no minimum hydraulic pressure for operation.
  • This valve exhibits a large degree of self-compensation in the 2-to-1 direction and will provide proportional flow control in the 1-to-2 direction with the addition of an external compensator.
  • Full reverse flow (1-to-2) with 100% command in the 1-to-2 direction is possible without a compensator under all conditions.
  • 50-psi (3,5-bar) minimum back pressure is recommended.
  • Extremely low leakage - 0.004 in3 (0.07 cc3)/min (1 drop/min)
  • A FULL DATA SHEET is available for this model using the link at the top of the page.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    2.6 gpm
  • Maximum Operating Pressure
    5000 psi
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    0.004 in³/min.@5000 psi
  • Viscosity Range
    35 - 2000 SUS
  • Response Time - Typical
    50 ms
  • Switching Frequency
    15,000 max. cycles/hr
  • Valve Hex Size
    3/4 in.
  • Valve Installation Torque
    20 - 25 lbf ft
  • Model Weight
    .30 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • U.S. Patent #
    10,302,201
  • Hysteresis (with dither)
    14%
  • Linearity (with dither)
    5%
  • Repeatability (with dither)
    7%
  • Recommended dither frequency
    100 Hz
  • Deadband, nominal (as a percentage of input)
    50%

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • Can FLeX proportional valves be driven with an explosion proof coil?
  • What is the difference between nominal and maximum flow capacity?
  • Do FLeX valves utilize a floating nose design?
  • Is the FLeX program available in QuickDesign SmartConnect?
  • What happens if I block the control flow (priority) port?
  • I have a heat problem, will Sun's priority flow control help?
  • How big is a drop of hydraulic oil?  
  • What is the pressure drop through a flow control?
  • What is the compensating pressure of Sun's flow controls?
  • How accurate are Sun's flow controls?
  • What happens if I block the bypass port on a priority flow control?
  • Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.
  • An additional 2.00 inches (50,8 mm) beyond the valve extension is needed for coil installation and removal.