Model

FSDAXAN

Control
Flow Split
Seal Material
Material/Coating

Model: FSDA

Closed center, flow divider-combiner valve

Cavity: T-32A | Capacity:

Model

FSDAXAN

Control
Flow Split
Seal Material
Material/Coating

Technical specifications

Closed-center flow divider/combiners are sliding-spool, pressure-compensated devices used to split flow in one direction and combine flow in the opposite direction. These valves may be used to accurately control two or more cylinders or hydraulic motors where bidirectional operation is required.

  • All flow divider and divider/combiner cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Operating characteristics cause the leg of the circuit with the greatest load to receive the higher percentage of flow in dividing mode. If a rigid mechanism is used to tie actuators together, the lead actuator may pull the lagging actuator and cause it to cavitate.
  • In combining mode, compensating characteristics will cause the leg of the circuit with the lowest load to receive the higher percentage of flow. If a synchronization feature is not included, an additive accuracy error will be experienced with each full stroke of the actuator.
  • In applications involving rigid mechanisms between multiple actuators, operating inaccuracy will cause the eventual lock-up of the system. If the mechanical structure is not designed to allow for the operating inaccuracy inherent in the valve, damage may occur.
  • In motor circuits, rigid frames or mechanisms that tie motors together, and/or complete mechanical synchronized motion of the output shaft of the motors, either by wheels to the pavement or sprockets to conveyors, will contribute to cavitation, lock-up and/or pressure intensification.
  • Variations in speed and lock-up can be attributed to differences in motor displacement, motor leakage, wheel diameter variance and friction of wheels on the driving surface.
  • Extreme pressure intensification can occur on multiple wheel drive vehicles.
  • Flow between ports is limited to spool leakage. This does not provide leak proof holding capability, but can be useful in minimizing cross flow and drift.
  • Divisional and combining accuracy are equal.
  • Below the minimum flow rating there is not enough flow for the valve to modulate. It is effectively a tee. If flow starts at zero and rises, there will be no dividing or combining control until the flow reaches the minimum rating.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    3 - 15 gpm
  • Maximum Operating Pressure
    5000 psi
  • Divisional Accuracy at Max Input Flow
    50% ±2.5%
  • Divisional Accuracy at Minimum Input Flow
    50% ±4.5%
  • Pressure Drop at Maximum Rated Input Flow
    350 psi
  • Pressure Drop at Minimum Rated Input Flow
    30 psi
  • Valve Hex Size
    1 1/8 in.
  • Valve Installation Torque
    45 - 50 lbf ft
  • Model Weight
    .60 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • How big do my slip orifices have to be?
  • Why does Sun use 2 slip orifices?
  • Why am I getting a higher inaccuracy than Sun claims?
  • Most of the dividing-combining inaccuracies will average out, won't they?
  • Most of Sun's divider-combiners will do better than the published specs, won't they?
  • Can I synchronize two cylinders with Sun's divider-combiner?
  • How big is a drop of hydraulic oil?  
  • What is the synchronizing feature?
  • How has Sun solved the hook breaking problem?