2-way, pilot-shifted, dual path, proportional throttle
Cavity: T-52AD | Capacity:
Technical specifications
This valve is a 2-way, 2-position proportional throttle. Ports 2 and 3 are normally closed. Pilot pressure at port 1 opposes the spring and creates a variable metering orifice between port 2 and 3 that is proportional to the pressure at 1. The force balance of the flow forces, spring and pilot pressure results in a degree of partial self-compensation as the load pressure changes. Pressure at port 4 directly opposes pressure at port 1. The valve uses a dual-path design. Ports 2 and 3 incorporate a double-port area.
- These valves may be pressure compensated by an external, modulating, logic element. Use LR_C-XHN for a bypass circuit or LP_C-XHN for a restrictive circuit.
- The valve provides a degree of self-compensation and may be used as a flow control. To increase the accuracy of flow control, an external, modulating, logic element can be used to maintain a constant flow over a wider range of flows and pressures. See performance curves for additional information.
- The optional L control is a stroke adjustment that limits maximum flow.
- Ports 1 and 4 should be limited to 500 psi (35 bar).
- Pressure at port 4 directly opposes pressure at port 1.
- Accurate pressure compensated control requires that a constant pressure differential be maintained across the valve.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity30 gpm
- Maximum Operating Pressure5000 psi
- Pilot Pressure Required to Shift Valve50 - 120 psi
- Pilot Pressure Required for Full Shift at Rated Flow290 - 340 psi
- Maximum Valve Leakage at 110 SUS (24 cSt)5 in³/min.@1000 psi
- Pilot Volume Displacement.05 in³
- Hysteresis35 %
- Valve Hex Size1 1/8 in.
- Valve Installation Torque45 - 50 lbf ft
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
How big is a drop of hydraulic oil?
- FTDAZ 2-way, pilot-shifted, dual path, proportional throttle with position switch
- When installed in Sun's standard T-52A line mount manifold, plug unused ports and expect higher pressure drops.
Highlights
Technical Tips
Technical Information