Loading...
Fixed-orifice, pressure compensated flow control valve
Cavity: T-8A | Capacity:
See CAD Files tab below to request images.
Technical specifications
Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. A variety of flow rates are available.
- Will accept 5000 psi (350 bar) at ports 1 and 2.
- Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- Flow Tolerances A Flow Rate +/- 2.0 in³/min. (+/- 32 cc/min.) B Flow Rate +/- 2.5 in³/min. (+/- 40 cc/min.) D and F Flow Rates +/- 3.0 in³/min. (+/- 48 cc/min.) H and J Flow Rates +/- 4.0 in³/min. (+/- 64 cc/min.) L Flow Rate +/- 4.5 in³/min. (+/- 72 cc/min.)
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity.5 gpm
- Maximum Operating Pressure5000 psi
- Valve Hex Size7/8 in.
- Valve Installation Torque20 - 25 lbf ft
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
What parts of the Sun cartridge valve are field serviceable?
How big is a drop of hydraulic oil?
Highlights
Technical Tips
Technical Information