Fixed-orifice, pressure compensated flow control valve
Cavity: T-162A | Capacity:
Technical specifications
Fixed-orifice, pressure-compensated flow controls provide precise flow regulation for meter-in or meter-out applications where there may be wide pressure fluctuations. The flow setting is specified by the user and is set at the factory.
- Customer must specify a flow rating. Factory set flow ratings are within +/- 15% of the requested setting.
- The tuneable control option provides +/- 20% variation from the nominal factory pre-set flow. Turn the adjustment clockwise to increase.
- All 2-port flow control cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size). However, cartridge extension dimensions from the mounting surface may vary.
- The sharp-edged orifice design minimizes flow variations due to viscosity changes.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity3 gpm
- Maximum Operating Pressure5000 psi
- Valve Hex Size3/4 in.
- Valve Installation Torque20 - 25 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Model Weight.20 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
How big is a drop of hydraulic oil?
- ADJ Reducer/reliever on P2
- ADP Reducer/reliever on P2
- U3G ISO 03: Cover manifold, reducer on P to A, tank to T
- U3K ISO 05: Reducer/reliever on P
- U3L ISO 05 - X&Y (Euro): Reducer/reliever on P
- U3M ISO 05 - X&Y (US): Reducer/reliever on P
- U3N ISO 07: Reducer/reliever on P
- U3S ISO 08: Reducer/reliever on P
- U4F ISO 03: Reducer on A with reverse flow check