Direct-acting relief valve - after check
Cavity: T-11A | Capacity:
Technical specifications
The relief-after-check cartridge is a CavitySaver™ (multi-function) valve incorporating a direct-acting relief tee'd in after a check function. The check valve flow is from the inlet (port 2) to the system port (port1). When the pressure in the system (port 1) reaches the relief valve setting, the valve starts to open to tank (port 3), throttling flow to limit the pressure rise. These valves are smooth and quiet, essentially zero-leak, dirt-tolerant, immune to silting and are very fast.
- Note! This valve deviates from Sun's normal flow path for relief valves. It is probably not useable in current Sun relief manifolds.
- This cartridge can be used to provide relief protection on the system side of the circuit.
- The seals on the adjust screw are exposed to system pressure which means this valve can only be adjusted when the pressure is removed. The setting procedure is; check the setting, remove the pressure, adjust the valve, check the new setting.
- Select a spring range where the desired relief setting is approximately mid-range to high between the minimum and maximum pressure to ensure maximum valve repeatability.
- Suitable for use in load holding applications.
- The check portion of the valve has a maximum leakage rate of less than 1 drop/minute (0,07 cc/min).
- The direct acting relief exhibits rapid response characteristics that minimize pressure overshoot and also provides low reseat leakage (less than 5 drops/min (0,3 cc/min) @ 85% of cracking pressure), check valve leackage is less than 1 drop/min (0,07 cc/min).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity10 gpm
- Maximum Operating Pressure5000 psi
- Check Cracking Pressure25 psi
- Factory Pressure Settings Established at4 gpm
- Maximum Valve Leakage at Reseat5 drops/min.
- Response Time - Typical10 ms
- Adjustment - No. of CW Turns from Min. to Max. setting6
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
What are the tolerances on pressure settings for Sun's pressure control valves?
Where would I use a kick-down relief?
Can I use a kick-down relief for my system relief?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
Highlights
Technical Tips
Technical Information