Loading...
Loading...

Model

LOJOZN

Seal Material

Pilot-to-close, spring-biased open, unbalanced poppet logic element with position switch

Cavity: T-19A | Capacity:

Loading...

Model

LOJOZN

Seal Material
See CAD Files tab below to request images.

Technical specifications

These unbalanced, pilot-to-close logic valves are 2-way switching elements that are spring biased open. Pressure at either work port 1 or 2 will tend to keep the valve open while pressure at port 3 will tend to close it. The force generated at port 3 must be greater than the sum of the forces acting at port 1 and port 2 plus the spring force for the valve to close. NOTE: The pilot area (port 3) is 1.8 times the area at port 1 and 2.25 times the area at port 2. This valve incorporates a position switch to provide confirmation that the valve is spring biased to the fully open position.

  • These valves have positive seals between port 2 and the pilot area.
  • This cartridge is supplied as a sealed, factory set unit and is not field serviceable. Any tampering will violate the product warranty.
  • When torquing this cartridge into its cavity, a crow's foot wrench or similar will be required since the position switch precludes the use of a deep socket wrench.
  • Because these valves are unbalanced, operation is pressure dependent. Opening and closing of the poppet are functions of the force balances on three areas: Port 1 = 100%, Port 2 = 80%, and the Pilot Area = 180%.
  • These valves are pressure responsive at all ports, therefore it is essential to consider all aspects of system operation through a complete cycle. Pressure changes at any one port may cause a valve to switch from a closed to an open position, or vice versa. All possible pressure changes in the complete circuit must be considered to assure a safe, functional system design.
  • All ports will accept 5000 psi (350 bar).
  • Position switch is CE approved.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    200 gpm
  • Maximum Operating Pressure
    5000 psi
  • Area Ratio, A3 to A1
    1.8:1
  • Area Ratio, A3 to A2
    2.25:1
  • Maximum Valve Leakage at 110 SUS (24 cSt)
    1 drops/min.
  • Pilot Passage into Valve
    .09 in.
  • Pilot Volume Displacement
    .42 in³
  • Valve Hex Size
    1 5/8 in.
  • Valve Installation Torque
    350 - 375 lbf ft
  • Model Weight
    3.10 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Supply Voltage
    20-30 VDC
  • Operating Temperature Range
    -25 to 80 °C
  • Vibration
    ≥ 50g, 0-500 impulses/sec
  • Shock
    >50 g, 1ms
  • Reverse Polarity Protection
    Yes
  • Maximum Output Load
    ≤ 400 mA, Duty Ratio 100%
  • Short Circuit Protection
    Yes, Load Short Unlimited
  • Turn On Time
    ≤ 25 ms
  • Hysteresis
    ≤ .002 in.
  • Thermal Shift - 0 to 80 °C ≤ ±
    .004 in.
  • EMC
    DIN EN 61000-6-1/2/3/4
  • Connector
    M12 X 1 (4) Pin
  • Connector Environment Rating
    IP65

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • I need to discharge a large accumulator. How can I increase the capacity of my discharge circuit?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?
  • LOJO Pilot-to-close, spring-biased open, unbalanced poppet logic element

Keep up with Sun