Model

MWDPDHN

4-Port Vented, Non-adjustable
Control
Factory Set
Seal Material
Material/Coating

Model: MWDP

Vented LoadMatch™ counterbalance valve

Cavity: T-21A | Capacity:

Model

MWDPDHN

4-Port Vented, Non-adjustable
Control
Factory Set
Seal Material
Material/Coating

Technical specifications

These valves are self-setting counterbalance valves which combine multiple functions in one package; reverse free flow, load, and thermal relief. The check allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting pilot function self adjusts to approximately 1.3 times the load induced pressure up to the thermal relief setting. Backpressure at port 2 does not affect self setting performance because the spring chamber references the vent (port 4).

  • The LoadMatch™ control allows the setting of the valve to dynamically adjust in response to load pressure, while still providing a fixed thermal relief setting. The control creates a dynamic setting that is lower than the thermal relief setting, but is never more than necessary to provide safe, reliable load control. Also, since the dynamic setting is lower than the thermal relief setting, the pilot pressure required to open the valve is typically lower than other load control valves with similar thermal relief settings.
  • LoadMatch™ control allows for lower pilot pressures under most loading conditions than other counterbalance valves with similar thermal relief settings.
  • Pilot pressures for LoadMatch™ control are nearly identical for any load pressure in the operational range.
  • All 4-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). Note: This valve has a larger hex size than what is typical for its cavity and special consideration should be given in existing applications.
  • Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
  • This valve is functionally a 4-port counterbalance valve. It seats as a poppet and modulates over a long stroke.
  • The maximum recommended load holding pressure for the G range is 4620 psi (319 bar). The cracking pressure for the G range will be 5800-6350 psi (400-438 bar).
  • The maximum recommended load holding pressure for the H range is 3080 psi (212 bar). The cracking pressure for the H range will be 3850-4250 psi (265-293 bar).
  • The maximum recommended load holding pressure for the J range is 3850 psi (265 bar). The cracking pressure for the J range will be 4800-5300 psi (331-365 bar).
  • The percentage difference between the cracking and the reseat values for the LoadMatch™ versions are identical. The setting tolerance is as noted.
  • Sun load control and counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • This valve has positive seals between all ports.
  • This valve has full relief capacity.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    15 gpm
  • Maximum Operating Pressure
    5000 psi
  • Maximum Recommended Load Pressure
    See Technical Features
  • Check Cracking Pressure
    25 psi
  • Factory Pressure Settings Established at
    2 in³/min.
  • Maximum Valve Leakage at Reseat
    5 drops/min.
  • Reseat
    ≥77% of setting
  • Valve Hex Size
    1.00 in.
  • Valve Installation Torque
    30 - 35 lbf ft
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • Why is turning the adjust screw for counterbalance valves opposite of most other valves?
  • What parts of the Sun cartridge valve are field serviceable?
  • You say your valves leak 5 drops/min. How can I keep my load from drifting?
  • How do I determine the setting of a counterbalance valve?
  • How do I know how much pilot pressure is required to lower a load with a counterbalance valve?
  • When should I use a vented counterbalance valve?
  • How does Sun test a counterbalance valve for leakage?  
  • How do I decide which pilot ratio to select?
  • How big is a drop of hydraulic oil?  
  • Why can't I use a counterbalance valve in a closed loop transmission circuit?  
  • What do you mean by the setting of a counterbalance valve and what should it be?
  • I don't need pilot assist. Can I just block port 3?
  • Can I use an atmospherically vented counterbalance valve instead of the four-port version to save on plumbing?
  • Why is it that your valves have pilot ratios below 10:1, while other manufacturers start at 7:1 and go up?
  • Why can't I block the pilot vent port? That area is positively sealed, isn't it?  
  • Should I replace the counterbalance valve if my cylinder is drifting or moving?
  • I have a pilot-to-open check on a large cylinder and the decompression is violent. Can I use a counterbalance instead?
  • How do I size a counterbalance valve?
  • Can I adjust a counterbalance valve in the field?
  • Why do you offer 2 check valve cracking pressures?
  • What happens to the counterbalance valve if I have backpressure in my system?
  • What do you mean by hysteresis when referring to a counterbalance valve?