Technical specifications

SUN gage line fuses protect systems from loss of oil if a gage or signal line breaks. If an object hits the gage or the fuse and breaks off the hex of the fuse, the line fuse will continue to perform its function because the working parts are located inside the port. The flow required to actuate the gage line fuse is 1.0 gpm (4 L/min).

  • Valve shuts off when flow exceeds 1 gpm (4 L/min.) +/- 20% or pressure differential exceeds 100 +/- 25 psi (7 bar +/- 1,7 bar).
  • Valve reopens when differential pressure drops below 80 +/- 20 psi (3 +/- 1,3 bar).
  • Arrow shows direction of closing flow.
  • Maximum Operating Pressure
    5000 psi
  • Seal Material
  • Material
    Zinc Plated Steel
  • Port Configuration
    SAE -6 (Male), SAE -4 (Female)
  • Port Size
    SAE 6