Minimum Control Pressure
Seal Material

Pilot-operated, pressure reducing/relieving main stage with drilled piston orifice and integral T-8A control cavity

Cavity: T-19A | Capacity:

Loading...

Model

PPJF8WN

Minimum Control Pressure
Seal Material

Technical specifications

This valve is a 3-way, normally open modulating element that incorporates an integral pilot control cavity. The pilot control cavity will accept any T-8A pressure control cartridge. The valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The pilot cartridge's setting determines the difference in pressure between reduced pressure (port 1) and the tank (port 3).

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Maximum inlet pressure is determined by the bias spring. The D spring is tested with 2000 psi (140 bar) maximum differential pressure and the W spring is tested with 5000 psi (350 bar) maximum inlet pressure.
  • NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve should then be installed into the main stage valve to its required torque value.
  • The -8 control option allows the pilot control valve to be incorporated directly into the end of the relief cartridge via the T-8A cavity. These pilot control cartridges are sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation. See Pilot Control Cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    80 gpm
  • Maximum Operating Pressure
    5000 psi
  • Control Pilot Flow
    15 - 20 in³/min.
  • Factory Pressure Settings Established at
    blocked control port (dead headed)
  • Pilot Control Cavity
    T-8A
  • Valve Hex Size
    1 5/8 in.
  • Valve Installation Torque
    350 - 375 lbf ft
  • Model Weight
    3.10 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • What are the tolerances on pressure settings for Sun's pressure control valves?
  • I need a reducer on B. Can I connect the drain to A?
  • How big is a drop of hydraulic oil?  
  • What do you mean by maximum differential?
  • Direct acting or pilot operated - what do I use?
  • Will your reducing/relieving valve relieve my pump to tank?
  • Can I back flow through a reducing valve from port 1 to port 2?
  • PPJF Pilot-operated, pressure reducing/relieving valve with drilled piston orifice
  • PPJF Pilot-operated, pressure reducing/relieving valve with drilled piston orifice
  • Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at point of use.

Keep up with Sun