Direct-acting, pressure reducing/relieving valve
Cavity: T-2A | Capacity:
Technical specifications
Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
- Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
- Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
- Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
- Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity20 gpm
- Maximum Operating Pressure5000 psi
- Factory Pressure Settings Established at0.25 gpm
- Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.
- Adjustment - No. of CW Turns from Min. to Max. setting5
- Valve Hex Size1 1/8 in.
- Valve Installation Torque45 - 50 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Model Weight.60 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
What are the tolerances on pressure settings for Sun's pressure control valves?
I need a reducer on B. Can I connect the drain to A?
How big is a drop of hydraulic oil?
What do you mean by maximum differential?
Direct acting or pilot operated - what do I use?
Will your reducing/relieving valve relieve my pump to tank?
Can I back flow through a reducing valve from port 1 to port 2?