Model: Q46
Ninety degree with reverse flow check - reducing
Cavity: T-24A
Function
Technical specifications
Modifiers
Ports
- Q46, /10, /11, /15, /16, /S, /S3, /S4, /V, /Y, /Y3, /Y4Ports 1, 2, 3: 1 1/2" Code 62 ; Port 4: SAE 6; Gage Port: 1/4" NPTF;
- Q46/1A, /1B, /1F, /1G, /M, /T, /T3, /T4, /W, /W3, /W4, /ZPorts 1, 2, 3: 1 1/2" Code 62 ; Port 4: 1/4" BSPP; Gage Port: 1/4" BSPP;
- Body TypeLine mount
- Cavity
- InterfaceNone
- Body FeaturesNinety degree with reverse flow check - reducing
- Includes integral cartridge(s)Yes (see Included Components)
- Mounting Hole ThreadM10x1.5 - 6H (metric models)
- Open Cavities1
- Port Size1 1/2" Code 62
- Mounting Hole Thread.375-16 UNC - 2B in.
- Mounting Hole Depth.62 in.
- Mounting Hole Quantity2
Why doesn't Sun anodize their aluminum bodies?
How big is a drop of hydraulic oil?
- Flange mounting hole data: Inch: 5/8-11 UNC x 1.38 (34,9 mm) DP, Metric: M16 x 2.0-6H x 1.38 (34,9 mm) DP
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.