Loading...
Loading...

Model

RBANXAN

Control
Adjustment Range
Seal Material
Coil

Electro-proportional relief valve - pilot capacity, high pressure setting with no command

Cavity: T-8A | Capacity:

Loading...

Model

RBANXAN

Control
Adjustment Range
Seal Material
Coil

Technical specifications

This 2-port, pilot-stage, direct-acting relief cartridge is an electro-proportionally controlled, normally-closed pressure regulating valve. The valve is spring biased closed to its highest setting (customer specified). Increasing current to the coil will proportionally decrease the pressure setting. When the pressure at port 1 (inlet) is sufficient to overcome the spring force minus the solenoid force, as determined by the analog input signal, the poppet lifts and allows flow from port 1 to port 2 (outlet). This pilot control cartridge utilizes the T-8A cavity so it can be used in conjunction with Sun's main stage, pressure control elements.

  • Customer must specify a relief setting that falls within the selected pressure range. This setting represents the maximum relief pressure which the valve will default to with no command. As the command increases, the relief setting will decrease. See performance curves for selected pressure range. This setting is not adjustable in the field.
  • Varying the analog input signal to the proportional solenoid provides a step-less control of pressure.
  • This electro-proportional cartridge utilizes the Sun T-8A, 2-port cavity making it the ideal choice to use in conjunction with Sun's main stage cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-port pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration.
  • High pilot capacity allows for operation of larger size main stage elements.
  • Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
  • Damped construction provides stable operation over a wide range of operating conditions.
  • Low leakage levels in the closed position. (Reseat occurs at 85% of cracking pressure.)
  • Coils are interchangeable with Sun's other full flow, solenoid operated valves and can be mounted on the tube in either direction.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    .25 gpm
  • Maximum Operating Pressure
    5000 psi
  • Maximum Valve Leakage at Reseat
    1.5 in³/min.
  • Reseat
    >85% of setting
  • Solenoid Tube Diameter
    .75 in.
  • Valve Hex Size
    7/8 in.
  • Valve Installation Torque
    20 - 25 lbf ft
  • Model Weight (with coil)
    1.00 lb
  • Seal and nut kit - Coil
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • Hysteresis (with dither)
    <4%
  • Hysteresis with DC input
    <8%
  • Linearity (with dither)
    <2%
  • Repeatability (with dither)
    <2%
  • Recommended dither frequency
    140 Hz

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • What are the tolerances on pressure settings for Sun's pressure control valves?
  • Where would I use a kick-down relief?
  • Can I use a kick-down relief for my system relief?
  • How big is a drop of hydraulic oil?  
  • How do I get a kick-down relief to reset?
  • Direct acting or pilot operated - what do I use?
Highlights
Technical Tips
Technical Information

Keep up with Sun