Direct-acting relief valve

Cavity: T-16A | Capacity:

Loading...

Model

RDHALACN

Control
Adjustment Range
Seal Material
Material/Coating
See CAD Files tab below to request images.

Technical specifications

Direct-acting relief cartridges are normally closed, pressure-limiting valves used to protect hydraulic components from pressure transients. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to limit the pressure rise. These valves are smooth and quiet, essentially zero leak, dirt tolerant, immune to silting and are very fast.

  • All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits.
  • The seals on the adjust screw are exposed to system pressure which means this valve can only be adjusted when the pressure is removed. The setting procedure is; check the setting, remove the pressure, adjust the valve, check the new setting.
  • Valve is relatively insensitive to varying oil temperatures and oil borne contamination.
  • Select a spring range where the desired relief setting is approximately mid-range to high between the minimum and maximum pressure to ensure maximum valve repeatability.
  • Suitable for use in load holding applications.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Test pressure for each range is as follows: A range - 2000 psi (138 bar), B range - 1000 psi (69 bar), C range - 4000 psi (276 bar), D range - 800 psi (55 bar), E range - 400 psi (28 bar), S range - 150 psi (10 bar), W range - 3000 psi (207 bar).
  • Reseat meets or exceeds 90% of crack pressure at test setting. Settings lower than the test pressure may result in lower reseat percentages.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    100 gpm
  • Maximum Operating Pressure
    5000 psi
  • Factory Pressure Settings Established at
    4 gpm
  • Maximum Valve Leakage at Reseat
    10 drops/min.
  • Response Time - Typical
    2 ms
  • Reseat
    >90% of setting
  • Adjustment - No. of CW Turns from Min. to Max. setting
    6
  • Valve Hex Size
    1 1/4 in.
  • Valve Installation Torque
    150 - 160 lbf ft
  • Adjustment Screw Internal Hex Size
    5/32 in.
  • Locknut Hex Size
    9/16 in.
  • Locknut Torque
    80 - 90 lbf in.
  • Model Weight
    1.30 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Files not yet avialable. Click below to request them.

  • What parts of the Sun cartridge valve are field serviceable?
  • What are the tolerances on pressure settings for Sun's pressure control valves?
  • Where would I use a kick-down relief?
  • Can I use a kick-down relief for my system relief?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?
  • U.S. Patent #4,742,846; European Patent Pending

Keep up with Sun