Loading...
Loading...

Model

RPITLAN

Control
Adjustment Range
Seal Material
Material/Coating

Anti-Shock, pilot-operated, balanced poppet relief valve

Cavity: T-16A | Capacity:

Loading...

Model

RPITLAN

Control
Adjustment Range
Seal Material
Material/Coating

Technical specifications

Pilot-operated, anti shock relief cartridges limit maximum system pressure and also limit the rate of pressure rise. The valve opens and then ramps closed at a constant speed, independent of settings and flows. The adjust screw determines the maximum (relief) setting and the minimum (threshold) setting.

  • All 2-port relief cartridges (except pilot reliefs) are physically and functionally interchangeable (same flow path, same cavity for a given frame size).
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits.
  • Not suitable for use in load holding applications.
  • When pressure at the inlet (port 1) exceeds the threshold setting, the valve opens to tank (port 2). The pilot section moves forward at a steady rate, increasing the setting by compressing the pilot spring. Maximum setting is achieved when the pilot section reaches a mechanical stop.
  • Valve provides protection for pumps and motors from pressure transients due to sudden load changes, especially variable displacement pumps, since the displacement mechanism is sometimes too slow to catch these pressure transients.
  • Valve provides protection for hydrostatic drives by reducing the jerk caused by sudden reversals. The valve is suitable for cross-port applications.
  • When used with a switching device, the valve can provide the ramp characteristic typically provided by proportional valves.
  • Small power units can be started against an anti shock relief to provide longer pump life.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    100 gpm
  • Maximum Operating Pressure
    5000 psi
  • Control Pilot Flow
    10 - 25 in³/min.
  • Factory Pressure Settings Established at
    4 gpm
  • Pressure Ramp Up Time
    300 - 500 ms
  • Response Time - Typical
    2 ms
  • Adjustment - No. of CW Turns from Min. to Max. setting
    4.5
  • Valve Hex Size
    1 1/4 in.
  • Valve Installation Torque
    150 - 160 lbf ft
  • Adjustment Screw Internal Hex Size
    5/32 in.
  • Locknut Hex Size
    9/16 in.
  • Locknut Torque
    80 - 90 lbf in.
  • Model Weight
    1.00 lb
  • Seal kit - Cartridge
  • Seal kit - Cartridge
  • U.S. Patent #
    6,039,070

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • What are the tolerances on pressure settings for Sun's pressure control valves?
  • Where would I use a kick-down relief?
  • Can I use a kick-down relief for my system relief?
  • How big is a drop of hydraulic oil?  
  • Direct acting or pilot operated - what do I use?
  • Patents: US#6,039,070; Germany EP 1 001 197; Japan #3,119,230
  • Patents: US#6,039,070; Germany EP 1 001 197; Japan #3,119,230

Keep up with Sun