Ventable, pilot-operated, balanced piston relief valve with drain to port 4
Cavity: T-23A | Capacity:
Technical specifications
Ventable, pilot-operated, balanced piston relief cartridges with external drain are normally closed pressure regulating valves. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to regulate the pressure. They provide a vent port (port 3) that connects between the main piston and pilot stage to provide for remote control by other pilot or 2-way valves and a drain (port 4) that makes them insensitive to back pressure. These valves are accurate, have low pressure rise vs. flow, they are smooth and quiet, and are moderately fast.
- Will accept maximum pressure at port 2; suitable for use in cross port relief circuits. If used in cross port relief circuits, consider spool leakage.
- Main stage orifice is protected by a 150-micron stainless steel screen.
- Not suitable for use in load holding applications due to spool leakage.
- Pressure at port 4 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity60 gpm
- Maximum Operating Pressure5000 psi
- Control Pilot Flow15 - 20 in³/min.
- Factory Pressure Settings Established at4 gpm
- Maximum Valve Leakage at 110 SUS (24 cSt)4 in³/min.@1000 psi
- Response Time - Typical10 ms
- Adjustment - No. of CW Turns from Min. to Max. setting5
- Valve Hex Size1 1/4 in.
- Valve Installation Torque150 - 160 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Model Weight1.60 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
What are the tolerances on pressure settings for Sun's pressure control valves?
Where would I use a kick-down relief?
Can I use a kick-down relief for my system relief?
How big is a drop of hydraulic oil?
Direct acting or pilot operated - what do I use?
- RVGD8 Ventable, pilot-operated, balanced piston relief main stage with integral T-8A control cavity and drain to port 4
Highlights
Technical Tips
Technical Information