Atmospherically referenced, direct-acting sequence valve with reverse flow check
Cavity: T-5A | Capacity:
Technical specifications
Atmospherically referenced, direct-acting sequence valves with reverse-flow check will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. Additionally, these valves incorporate an integral check valve to provide reverse flow from port 2 (sequence) to port 1 (inlet). The pressure setting of this sequence valve controls the pressure at port 1 relative to the atmospheric vent.
- Suitable for use in load holding applications.
- Atmospherically referenced valves should only be used where it is impossible have a drain connection. Over time, the atmospherically referenced valves may leak externally or allow moisture into the spring chamber.
- Approximately 1 drop (0,07 cc) of fluid will pass into the vented spring chamber every 4000 cycles.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity30 gpm
- Maximum Operating Pressure5000 psi
- Check Cracking Pressure25 psi
- Factory Pressure Settings Established at2 in³/min.
- Maximum Valve Leakage at Reseat10 drops/min.
- Response Time - Typical2 ms
- Adjustment - No. of CW Turns from Min. to Max. setting5
- Valve Hex Size1 1/8 in.
- Valve Installation Torque45 - 50 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Model Weight.60 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
Model CAD Files
Symbol CAD Files
What parts of the Sun cartridge valve are field serviceable?
What are the tolerances on pressure settings for Sun's pressure control valves?
What does Sun mean by the term sequencing?
How big is a drop of hydraulic oil?
Highlights
Technical Tips
Technical Information