Loading...
Loading...

Model

SDJTLAN

Control
Adjustment Range
Seal Material
Material/Coating

Anti-Shock, pilot-operated, balanced poppet sequence valve with drain to port 3

Cavity: T-19A | Capacity:

Loading...

Model

SDJTLAN

Control
Adjustment Range
Seal Material
Material/Coating

Technical specifications

Pilot-operated, anti shock sequence cartridges limit maximum system pressure and also limit the rate of pressure rise. The valve opens and then ramps closed at a constant speed, independent of settings and flows. The adjust screw determines the maximum (relief) setting and the minimum (threshold) setting. The external drain makes the valve insensitive to pressure at port 2.

  • Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits.
  • Because the modulating occurs inside the cartridge, these valves are immune to most of the problems associated with cavitation, namely noise and manifold erosion.
  • Valve is relatively insensitive to varying oil temperatures and oil borne contamination.
  • Not suitable for use in load holding applications.
  • When pressure at the inlet (port 1) exceeds the threshold setting, the valve opens to tank (port 2). The pilot section moves forward at a steady rate, increasing the setting by compressing the pilot spring. Maximum setting is achieved when the pilot section reaches a mechanical stop.
  • The main stage orifice is protected against contamination.
  • Not suitable for sequencing cylinders.
  • Pressure settings are insensitive to back pressure at port 2.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
  • Cavity
  • Series
  • Capacity
    120 gpm
  • Maximum Operating Pressure
    5000 psi
  • Control Pilot Flow
    10 - 25 in³/min.
  • Factory Pressure Settings Established at
    4 gpm
  • Pressure Ramp Up Time
    200 - 400 ms
  • Response Time - Typical
    2 ms
  • Adjustment - No. of CW Turns from Min. to Max. setting
    4.5
  • Valve Hex Size
    1 5/8 in.
  • Valve Installation Torque
    350 - 375 lbf ft
  • Adjustment Screw Internal Hex Size
    5/32 in.
  • Locknut Hex Size
    9/16 in.
  • Locknut Torque
    80 - 90 lbf in.
  • Seal kit - Cartridge
  • Seal kit - Cartridge

Model CAD Files

Click the link of the file format you want to download.

Symbol CAD Files

Click the link of the file format you want to download.

  • What parts of the Sun cartridge valve are field serviceable?
  • What are the tolerances on pressure settings for Sun's pressure control valves?
  • What does Sun mean by the term sequencing?
  • How big is a drop of hydraulic oil?  