Anti-Shock, pilot-operated, balanced poppet sequence valve with drain to port 3
Cavity: T-19A | Capacity:
Technical specifications
Pilot-operated, anti shock sequence cartridges limit maximum system pressure and also limit the rate of pressure rise. The valve opens and then ramps closed at a constant speed, independent of settings and flows. The adjust screw determines the maximum (relief) setting and the minimum (threshold) setting. The external drain makes the valve insensitive to pressure at port 2.
- Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Will accept maximum pressure at port 2; suitable for use in cross port relief circuits.
- Because the modulating occurs inside the cartridge, these valves are immune to most of the problems associated with cavitation, namely noise and manifold erosion.
- Valve is relatively insensitive to varying oil temperatures and oil borne contamination.
- Not suitable for use in load holding applications.
- When pressure at the inlet (port 1) exceeds the threshold setting, the valve opens to tank (port 2). The pilot section moves forward at a steady rate, increasing the setting by compressing the pilot spring. Maximum setting is achieved when the pilot section reaches a mechanical stop.
- The main stage orifice is protected against contamination.
- Not suitable for sequencing cylinders.
- Pressure settings are insensitive to back pressure at port 2.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity120 gpm
- Maximum Operating Pressure5000 psi
- Control Pilot Flow10 - 25 in³/min.
- Factory Pressure Settings Established at4 gpm
- Pressure Ramp Up Time200 - 400 ms
- Response Time - Typical2 ms
- Adjustment - No. of CW Turns from Min. to Max. setting4.5
- Valve Hex Size1 5/8 in.
- Valve Installation Torque350 - 375 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Seal kit - Cartridge
- Seal kit - Cartridge