Loading...
Direct-acting sequence valve without reverse flow check
Cavity: T-11A | Capacity:
Technical specifications
Direct-acting sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port 1 relative to the pressure at the drain (port 3).
- All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
- Although this is a zero pilot flow valve, port 3 (drain) must be connected to maintain a pressure reference in the control chamber. If port 3 is blocked, reciprocating seal weepage will cause the valve to malfunction.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Suitable for use in load holding applications.
- Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
- Cavity
- Series
- Capacity15 gpm
- Maximum Operating Pressure5000 psi
- Factory Pressure Settings Established at2 in³/min.
- Maximum Valve Leakage at Reseat10 drops/min.
- Response Time - Typical2 ms
- Adjustment - No. of CW Turns from Min. to Max. setting4
- Valve Hex Size7/8 in.
- Valve Installation Torque30 - 35 lbf ft
- Adjustment Screw Internal Hex Size5/32 in.
- Locknut Hex Size9/16 in.
- Locknut Torque80 - 90 lbf in.
- Model Weight.30 lb
- Seal kit - Cartridge
- Seal kit - Cartridge
- Seal kit - Cartridge