Loading...
Loading...

Model

VLW

   
   
Modifier
Model: VLW

3 Station, Parallel circuit with relief cavity

Cavity: T-3A

Loading...

Model

VLW

   
   
Modifier
Function
Function image

Technical specifications

  • Modifiers
    Ports
    • VLW, /10, /11, /15, /16, /S, /S3, /S4, /V, /Y, /Y3, /Y4
      Ports A, B, P: SAE 16; Port T: SAE 20; Gage Port: SAE 4; Port Y: SAE 8;
    • Body Type
      Bar Manifold
    • Cavity
    • Interface
      ISO 08
    • Body Features
      3 Station, Parallel circuit with relief cavity
    • Open Cavities
      1
    • Port Size
      SAE 16
    • Mounting Hole Thread
      .500-13 UNC - 2B in.
    • Mounting Hole Depth
      .88 in.
    • Mounting Hole Quantity
      4
    • Why doesn't Sun anodize their aluminum bodies?
    • How big is a drop of hydraulic oil?  
    • For mounting bracket information, see catalog or drawing 991-021-***
    • ISO 08 Sandwich pattern mounting holes: .500-13 UNC x 1.16 DP, typical 18 places
    • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
    • Part
      Description
      Quantity
    • A330-006-006
      SAE Plug
      2