Loading...
Model: VRN
3 Station, Parallel circuit with relief cavity
Cavity: T-3A
See CAD Files tab below to request images.
Function
Technical specifications
Modifiers
Ports
- VRN, /10, /11, /15, /16, /S, /S3, /S4, /V, /Y, /Y3, /Y4Ports A, B, P: SAE 12; Port T: SAE 16; Port Y: SAE 6; Gage Port: SAE 4;
- Body TypeBar Manifold
- Cavity
- InterfaceISO 05 - X&Y (Euro)
- Body Features3 Station, Parallel circuit with relief cavity
- Open Cavities1
- Port SizeSAE 12
- Mounting Hole ThreadM10x1.5 - 6H
- Mounting Hole Depth.75 in.
- Mounting Hole Quantity4
Why doesn't Sun anodize their aluminum bodies?
How big is a drop of hydraulic oil?
- For mounting bracket information, see catalog or drawing 991-021-***
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.
Highlights
Technical Tips
Technical Information
- PartDescriptionQuantity
- A330-006-004SAE Plug2