Loading...
Loading...

Model

WKX

Modifier
Model: WKX

Danfoss OMT: Cross pilot with shuttle

Cavity: T-2A

Loading...

Model

WKX

Modifier
See CAD Files tab below to request images.
Function
Function image

Technical specifications

  • Modifiers
    Ports
    • WKX, /10, /11, /15, /16, /S, /S3, /S4, /V, /Y, /Y3, /Y4
      Ports V1 & V2: 3/4" NPTF; Port S: SAE 4;
    • Body Type
      Motor mount
    • Cavity
    • Interface
      Danfoss OMT
    • Body Features
      Cross pilot with shuttle
    • Open Cavities
      2
    • Port Size
      3/4" NPTF

    Model CAD Files

    Files not yet avialable. Click below to request them.

    • Why doesn't Sun anodize their aluminum bodies?
    • How big is a drop of hydraulic oil?  
    • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.

    Keep up with Sun