Loading...
Loading...

Model

WWG

   
   
Modifier
Model: WWG

Danfoss OMP/OMR: Cushion lock with make up checks and shuttle

Cavity: T-11A

Loading...

Model

WWG

   
   
Modifier
Function
Function image

Technical specifications

  • Modifiers
    Ports
    • WWG, /10, /11, /15, /16, /S, /S3, /S4, /V, /Y, /Y3, /Y4
      Ports T, V1, V2: SAE 10; Port S: SAE 4;
    • Body Type
      Motor mount
    • Cavity
    • Interface
      Danfoss OMP/OMR
    • Body Features
      Cushion lock with make up checks and shuttle
    • Open Cavities
      2
    • Port Size
      SAE 10
    • Mounting Hole Diameter
      .34 in.
    • Mounting Hole C'bore Diameter
      .53 in.
    • Mounting Hole C'bore Depth
      .43 in.
    • Mounting Hole Quantity
      4
    • Why doesn't Sun anodize their aluminum bodies?
    • How big is a drop of hydraulic oil?  
    • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.